ActSafe PME Bedienungsanleitung Seite 27

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 26
27
User’s Manual PME Ascender 4-stroke engine
TROUBLE SHOOTING GUIDE
If this guide does not solve your problems,
rst check the engine manual for further
trouble shooting guide and then contact
ActSafe Systems AB or by ActSafe approved
distributor.
TROUBLE SHOOTING GUIDE
The engine does not start
The lifting capacity is notably weak
The grab on the rope is poor, the rope slips
PROBABLE CAUSE REMEDY
Empty tank Refuel the ascender.
Ignition cable loose Reattach the ignition cable to the spark plug.
Wrong fuel Empty the tank, clean and refuel the ascender.
Wrong carburettor settnings Set the carburettor, see service instructions.
PROBABLE CAUSE REMEDY
The fuel is wrong Change to recommended fuel.
The winch is being used at
high altitude.
High altitude will result in loss of performance. The engine can be equipped
for use at high altitude. Contact ActSafe or an approved distributor.
The engine is in bad condition Service the engine.
PROBABLE CAUSE REMEDY
Rope connected incorrectly Reconnect the rope.
The rope is not suitable
for the ascender
Change the rope.
The rope grab is worn
The ascender is in need of repair and service, contact ActSafe
or an approved distributor.